Offline — the draft stays saved on this device.
Gas pipe sizing calculator

Gas pipe sizing calculator

Appliance input, pipe length, gas type and allowed pressure drop: you get gas flow, minimum inside diameter and the copper tube size.

Deterministic calculation in your browser. No signup to see the result.

Minimum inside diameter

15.94 mm Ø

  • Gas flow2.24 m³/h
  • Minimum inside diameter15.94 mm Ø
  • Copper tube size (outside diameter)18 mm Ø

Your prices per language/currency. Used when you enable “Use my prices” in calculators. My prices →

Calculate labour, margin & GST

How it's calculated (visible formula)

Q = input ÷ heating value; Renouard: D = (23,200 × SG × L × Q^1.82 ÷ ΔP)^(1/4.82)

See methodology and formula versions

How to calculate it, step by step

  1. Take the appliance input rating (nameplate or spec sheet).
  2. Convert to gas flow with the gas's heating value.
  3. Measure pipe length and add about 20% for fittings.
  4. Set the allowable pressure drop.
  5. Work out diameter and pick the next larger stock size.

Worked example: 82,000 BTU/h (24 kW) tankless on natural gas, 33 ft, 1 mbar drop

  1. Q = 24 ÷ 10.7 ≈ 2.24 m³/h (79 CFH)
  2. D ≈ 15.9 mm

→ 18 mm copper (16 mm ID) — about a ⅝–¾ in line.

Common mistakes

Pro tips

From calculation to quote

Add labour, overhead and your margin, and generate the professional PDF.

FAQs

How big a gas line for a tankless water heater?
Many 199,000 BTU units need ¾ in; check the IFGC/NFPA 54 tables for your length.
What pressure drop is allowed?
US tables typically use 0.5 in w.c. (≈ 1.2 mbar) for low-pressure natural gas.
Can I use CSST?
Yes, if sized from the maker's tables and bonded per code.
What size gas line for a tankless heater?
Often ¾ in; check your local code tables for length and BTU.
Natural gas or propane?
Propane has higher heating value, so it needs less flow and smaller pipe.
What is equivalent length?
Actual length plus fittings converted to feet of pipe.

Sources and standards

Maintained by · Formula v1.0.0 · Verified 2026-09-10 · Updated 2026-09-10 · Limits: quantity estimation, not structural design or site supervision.