Water heater sizing calculator

Water heater sizing calculator

Hot water flow and inlet and outlet temperatures: you get the heat output needed, the equivalent heater rating and gas use.

Deterministic calculation in your browser. No signup to see the result.

Required output

20.93 kW

  • Required output20.93 kW
  • Equivalent heater rating (l/min at 25 °C rise)12 l/min
  • Natural gas use2.17 m³/h

Your prices per language/currency. Used when you enable “Use my prices” in calculators. My prices →

Calculate labour, margin & GST

How it's calculated (visible formula)

P (kW) = flow (l/s) × 4.186 × ΔT; 1 kW = 3,412 BTU/h

See methodology and formula versions

How to calculate it, step by step

  1. Decide how much hot water you need at once (gpm).
  2. Take winter inlet water temperature.
  3. Set the desired outlet temperature.
  4. Output = flow × 4.186 × temperature rise (kW).
  5. Pick a heater rated for that flow at your rise.

Worked example: 2.6 gpm (10 l/min) shower, 50 to 104 °F

  1. 10 ÷ 60 × 4.186 × 30 = 20.9 kW
  2. ≈ 71,400 BTU/h output

→ A unit giving ~3 gpm at a 54 °F rise (about 85,000 BTU input).

Common mistakes

Pro tips

From calculation to quote

Add labour, overhead and your margin, and generate the professional PDF.

FAQs

How many GPM do I need?
Add up fixtures running at once: shower 2–2.5, faucet 1–1.5, dishwasher 1–1.5.
What temperature rise should I use?
Winter inlet to about 105–120 °F — often 60–70 °F in the north.
Electric tankless?
Whole-house units can need 100–150 A at 240 V.
What size tankless for two showers?
About 5 gpm at your winter rise — often 180–199k BTU gas.
How many kW for a tankless electric?
Whole-house units are 18–36 kW.
Tank or tankless?
Tanks store a reserve; tankless gives endless hot water within its flow limit.

Sources and standards

Maintained by · Formula v1.0.0 · Verified 2026-09-10 · Updated 2026-09-10 · Limits: quantity estimation, not structural design or site supervision.