Heat pump balance point calculator

Heat pump balance point calculator

Design load, design and indoor temperatures, and heat pump capacity at 7 °C and −7 °C (45 °F and 19 °F): you get the balance point and backup heat at design conditions.

Deterministic calculation in your browser. No signup to see the result.

Backup heat at design temperature

2.14 kW

  • Balance point-0.7 °C
  • Load at balance point6.62 kW
  • Heat pump capacity at design temperature5.86 kW
  • Backup heat needed at design temperature2.14 kW

Your prices per language/currency. Used when you enable “Use my prices” in calculators. My prices →

Calculate labour, margin & GST

How it's calculated (visible formula)

load(T) = design load × (Ti − T) ÷ (Ti − Td); capacity linear between 7 °C and −7 °C; balance where load = capacity

See methodology and formula versions

How to calculate it, step by step

  1. Work out the heating load at outdoor design temperature.
  2. Set the indoor setpoint.
  3. Look up heat pump capacity at 47 °F and 17 °F (or 7 °C / −7 °C).
  4. Find where load and capacity meet.
  5. Work out backup heat needed on the coldest day.

Worked example: 8 kW load at 23 °F (−5 °C), 68 °F indoors, 8 kW at 45 °F and 5.5 kW at 19 °F

  1. Load: 0.32 kW per °C
  2. Capacity: 5.5 + 0.179 × (T + 7)
  3. Equal at −0.7 °C

→ Balance point ≈ 31 °F; at 23 °F you need 2.1 kW (7,300 BTU/h) of backup.

Common mistakes

Pro tips

From calculation to quote

Add labour, overhead and your margin, and generate the professional PDF.

FAQs

What is the balance point?
The outdoor temperature where heat pump output exactly meets the home's heat loss.
Where do I find capacity at 17 °F?
In the AHRI/NEEP cold-climate listing or the maker's extended tables.
What design temperature should I use?
The ASHRAE 99% heating design temperature for your location.
Why does capacity drop in the cold?
There's less heat to extract from colder air.
Is a high balance point bad?
It means more hours on backup and higher bills.
How much does strip heat cost?
1 kW of strip heat uses 1 kW; a heat pump uses 2–4× less per kW of heat.

Sources and standards

Maintained by · Formula v1.0.0 · Verified 2026-09-10 · Updated 2026-09-10 · Limits: quantity estimation, not structural design or site supervision.